MIAL
  • Air ProMIAL

MIAL

The following is about MIAL,i hope to help you better understand MIAL.

Send Inquiry

Product Description

Introduction

825 alloy sheathed series mineral insulated heating cable can meet the requirements of high temperature conditions and high heating power (up to 269W/m).The maximum temperature of 825 alloy sheathed heating cable provided by MICH can reach 800℃; conductor resistance value ranges from 2.1 Ω / km to 36100 Ω/km. 825 alloy sheathed series mineral insulated heating cable possesses excellent mechanical strength and advanced corrosion resistance. The heating cable of series resistance provided by MICH can meet the requirements of different power grade.

 

Cable Structure

 

Application of MIAL​

High temperature pipeline heat tracing

Anti-coagulation and viscositydecreasingforprocess media

Tank/vessel heating

Metal manufacturing industry --low melting point alloy melting

Extruder shell heating

Recycling of nuclear fuel waste

All kinds ofindustrial electric heaters

 

 

Specification of MIAL​

1.Heating cable instruction code

    

                                                                                                      

2.Cable Code


 

Table 1  Structure of Cable Element


Table 2 Heating Cable Specification (600V Single Core)

Cable Code

Diameter

Nominal resistanceat+20℃

Maximum manufacturing length

Unit weight

mm

Ω/m

m

kg/km

16C2.1

6.8

0.0021

130

220.7

16C3.4

5.9

0.0034

173

162.5

16C5.3

5.3

0.0053

214

125.6

16C8.5

4.8

0.0085

261

101.6

16C13

4.3

0.013

325

79.1

16C21

4.0

0.021

376

65.8

16K40

5.8

0.04

179

157.1

16K50

5.4

0.05

206

135.6

16K60

5.2

0.06

222

122.8

16K80

4.8

0.08

261

101.2

16K100

4.7

0.1

200

99.5

16K120

4.5

0.12

200

88.8

16K160

6.5

0.16

200

202.2

16K200

5.9

0.2

200

166.5

16K250

5.3

0.25

215

131.7

16K400

4.7

0.4

280

96.7

16K500

4.5

0.5

300

87.7

16N630

4.3

0.63

185

82.2

16N1000

3.9

1.0

230

62.8

16N1600

3.6

1.6

270

52.4

16N2500

3.4

2.5

300

45.6

16N2800

3.4

2.8

300

45.2

16N3300

3.4

3.3

300

44.7

16N4000

3.2

4.0

350

38.1

16N5200

3.2

5.2

350

37.7

16N6300

3.2

6.3

350

38.4

16N10000

3.2

10

350

38.9

 

Table 3 Heating Cable Specification (600V Double Cores)

Cable Code

Diameter

Nominal resistanceat+20℃

Maximum manufacturinglength

Unit weight

mm

Ω/m

m

kg/km

26K8.4

11.8

0.0084

43

632.9

26K13.4

9.8

0.0134

63

431.5

26K21

8.8

0.021

78

339.0

26K34

8.0

0.034

94

273.7

26K54

7.1

0.054

119

212.4

26K85

6.4

0.085

147

170.2

26K130

6.0

0.13

167

147.8

26K180

7.9

0.18

96

271.9

26K260

7.4

0.26

110

234.2

26K360

6.8

0.36

130

195.5

26K500

6.4

0.5

100

171.2

26K650

5.9

0.65

100

144.8

26K1000

5.7

1.0

100

133.3

26K1300

6.2

1.3

100

160.6

26K2000

5.8

2.0

100

139.1

26K3300

5.4

3.3

100

118.8

26N4600

5.8

4.6

100

138.3

26N8000

5.4

8.0

100

118.6

26N13000

5.0

13.0

100

100.8

26N27000

4.8

27.0

100

92.1

26N40000

4.6

40.0

100

84.4

26N60000

4.4

60.0

100

77.1

26N72000

4.2

72.0

100

70.2

 

Table 4 Heating Cable Specification (300V Double Cores)

Cable Code

Diameter

Nominal resistanceat+20℃

Maximum manufacturing length

Unit weight

mm

Ω/m

m

kg/km

23K210

5.2

0.21

222

117.9

23K300

4.8

0.3

261

98.9

23K400

4.8

0.4

261

97.2

23K480

4.8

0.48

261

96.0

23K650

4.6

0.65

284

87.3

23K1000

4.1

1.0

100

68.9

23K1300

3.8

1.3

100

58.9

23K2000

5.0

2.0

100

104.7

23K2400

4.8

2.4

100

95.7

23K3000

4.6

3.0

100

87.3

23N4600

4.8

4.6

100

96.3

23N7500

4.6

7.5

100

86.9

23N11200

4.4

11.2

100

78.7

23N14000

4.2

14.0

100

71.6

23N18000

3.6

18.0

100

52.6

23N26000

3.6

26.0

100

52.2

23N40000

3.4

40.0

100

46.4

23N50000

4.0

50.0

100

63.8

23N60000

3.6

60.0

100

51.7

23N72000

3.4

72.0

100

46.1

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals.

 

Table 5 terminal specifications of MIAL​

 

Model: A, D, E

Model: B

Maximum Voltage(V)

Maximum Current(A)

Terminal Specification

Maximum Current(A)

Terminal Specification

 

 

600

15

E2

20

E1

600

20

E2

25

E2

600

30

E3

40

E2

600

50

E3

70

E2

600

70

E3

100

E3

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.

 

Corresponding reference table between the output power and sheath temperature

 


Anticorrosive specification of MIAL​

Material

 

 

Sulfate

good

 

Hydrochloric acid

good

 

Hydrofluoric acid

good

 

Phosphate

good

 

Carbonate

good

 

Organic acid

good

 

Alkali metal

good

 

Sea water

good

 

Chloride

good

 

 

Explosion-proof instructions of MIAL

MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to Ⅱ A, Ⅱ B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.





Hot Tags: MIAL, China, Supplier, Manufacturer, Factory, Buy, Price List, Quality, Customized, Durable, Years Warranty, Free Sample

Related Category

Send Inquiry

Please feel free to give your inquiry in the form below. We will reply you within 24 hours.
验证码,看不清楚?请点击刷新验证码