MISS
  • Air ProMISS

MISS

The following is about MISS,i hope to help you better understand MISS.

Send Inquiry

Product Description

Introduction of MISS​

Mineral Insulated Heating Cable of Stainless steel sheath series can meet the requirements of high temperature condition and high heating power (up to 269W/m).The maximum heating temperature can reach up to 600℃. Conductor resistance value ranges from 2.1 to 36100Ω/km supplied by MICH. Mineral insulated heating cable possesses excellent mechanical strength and corrosion resistance. The heating cable of series resistance can meet the requirements of different power.

 

Cable Structure of MISS​

 

Application of MISS​

Nuclear industry

construction -- asphalt heating

Metal manufacturing industry-low melting point alloy melting

tank/vessel heating

Shell heatingfor the extruder

Heat tracing for high temperature industrial piping

anticoagulation and viscosity reduction of process media

All kinds of industrial electric heaters

 

Specification of MISS​

1.Heating cable instruction code

    

                                                                          

2.Cable Code


 

Table 1  Structure of Cable Element

 


Table 2 Heating Cable Specification (600V Single Core)

Cable Code

Diameter

Nominal resistanceat+20℃

Maximum manufacturing length

Unit weight

mm

Ω/m

m

kg/km

16C2.1

6.8

0.0021

130

184.2

16C3.4

5.9

0.0034

173

138.7

16C5.3

5.3

0.0053

214

111.9

16C8.5

4.8

0.0085

261

91.8

16C13

4.3

0.013

325

73.7

16C21

4.0

0.021

376

63.8

16K40

5.8

0.04

179

164.7

16K50

5.4

0.05

206

140.1

16K60

5.2

0.06

222

126.7

16K80

4.8

0.08

261

106.8

16K100

4.7

0.1

200

100.0

16K120

4.5

0.12

200

90.2

16K160

6.5

0.16

200

77.7

16K200

5.9

0.2

200

110.0

16K250

5.3

0.25

215

92.1

16K400

4.7

0.4

280

74.0

16K500

4.5

0.5

300

66.2

16N630

4.3

0.63

185

94.1

16N1000

3.9

1.0

230

91.3

16N1600

3.6

1.6

270

88.2

16N2500

3.4

2.5

300

69.8

16N2800

3.4

2.8

300

76.0

16N3300

3.4

3.3

300

68.9

16N4000

3.2

4.0

350

68.5

16N5200

3.2

5.2

350

68.2

16N6300

3.2

6.3

350

55.5

16N10000

3.2

10

350

41.7

 

Table 3 Heating Cable Specification (600V Double Cores)

Cable Code

Diameter

Nominal resistanceat+20℃

Maximum manufacturinglength

Unit weight

mm

Ω/m

m

kg/km

26K8.4

11.8

0.0084

43

636.1

26K13.4

9.8

0.0134

63

433.7

26K21

8.8

0.021

78

340.7

26K34

8.0

0.034

94

275.2

26K54

7.1

0.054

119

213.6

26K85

6.4

0.085

147

171.2

26K130

6.0

0.13

167

148.6

26K180

7.9

0.18

96

273.3

26K260

7.4

0.26

110

235.4

26K360

6.8

0.36

130

196.6

26K500

6.4

0.5

100

172.1

26K650

5.9

0.65

100

145.6

26K1000

5.7

1.0

100

134.1

26K1300

6.2

1.3

100

161.5

26K2000

5.8

2.0

100

139.8

26K3300

5.4

3.3

100

119.5

26N4600

5.8

4.6

100

139.0

26N8000

5.4

8.0

100

119.2

26N13000

5.0

13.0

100

101.3

26N27000

4.8

27.0

100

92.6

26N40000

4.6

40.0

100

84.9

26N60000

4.4

60.0

100

77.5

26N72000

4.2

72.0

100

70.6

 

Table 4 Heating Cable Specification (300V Double Cores)

Cable Code

Diameter

Nominal resistanceat+20℃

Maximum manufacturing length

Unit weight

mm

Ω/m

m

kg/km

23K210

5.2

0.21

222

118.5

23K300

4.8

0.3

261

99.4

23K400

4.8

0.4

261

97.7

23K480

4.8

0.48

261

96.5

23K650

4.6

0.65

284

87.8

23K1000

4.1

1.0

100

69.3

23K1300

3.8

1.3

100

59.3

23K2000

5.0

2.0

100

105.3

23K2400

4.8

2.4

100

96.2

23K3000

4.6

3.0

100

87.8

23N4600

4.8

4.6

100

96.8

23N7500

4.6

7.5

100

87.4

23N11200

4.4

11.2

100

79.2

23N14000

4.2

14.0

100

72.0

23N18000

3.6

18.0

100

52.9

23N26000

3.6

26.0

100

52.5

23N40000

3.4

40.0

100

46.6

23N50000

4.0

50.0

100

64.2

23N60000

3.6

60.0

100

52.0

23N72000

3.4

72.0

100

46.4

Note:

The resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

If not specified, the sheath material is based on SS 321;

For the use of 660V voltage occasions, please contact our company professionals.

 

Table 5 terminal specifications

 

Model: A, D, E

Model: B

Maximum Voltage(V)

Maximum Current(A)

TerminalSpecification

Maximum Current(A)

TerminalSpecification

600

15

E2

20

E1

600

20

E2

25

E2

600

30

E3

40

E2

600

50

E3

70

E2

600

70

E3

100

E3

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If increase or decrease of length required, please contact our professional personnel.

 

Corresponding reference table between the output power and sheath temperature

 


Anticorrosive specification of MISS​

Material

 

 

Sulfate

Not Recommend

 

Hydrochloric acid

Not Recommend

 

Hydrofluoric acid

Not Recommend

 

Phosphate

Not Recommend

 

Carbonate

According to the real Data

 

Organic acid

Applicable at any condition

 

Alkali metal

Acceptable

 

Sea water

Not Recommend

 

Chloride

Not Recommend

 

 

Explosion-proof instructions of MISS

MISS series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to Ⅱ A, Ⅱ B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.





Hot Tags: MISS, China, Supplier, Manufacturer, Factory, Buy, Price List, Quality, Customized, Durable, Years Warranty, Free Sample

Related Category

Send Inquiry

Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
验证码,看不清楚?请点击刷新验证码